Understanding Dial Indicator Simulator
A dial indicator makes tiny movements visible. Its plunger slides in and out by amounts far too small to judge by eye, and a hand on a round dial swings through a large angle in response. The dial shows the movement in steps of 0.01 mm.
The magnifying is done by gears. The plunger has a row of teeth cut along it, called a rack, which turns a small gear as the plunger moves. A train of further gears steps the motion up, so that 1 mm of travel takes the large hand once round the dial.
The dial has 100 divisions, so each one stands for a hundredth of a millimetre. If the scale is about 150 mm round, the divisions are about 1.5 mm apart. A movement of 0.01 mm at the plunger then shows as 1.5 mm at the tip of the hand, a magnification of about 150 times.
One turn of the hand covers only a millimetre, so a second, smaller dial counts the turns. Reading the indicator means adding the two. The small dial gives the whole millimetres and the large dial gives the hundredths.
Suppose the small hand lies between 2 and 3 and the large hand points at 64. The travel is 2 plus 64 times 0.01, which is 2.64 mm. The small hand is read as the last number it has fully passed, not the nearest one.
That rule matters most near the end of a turn. With the large hand on 96, the small hand looks as if it has reached 5. It has not, because the large hand is still four divisions short of zero, so the reading is 4.96 mm.
An indicator is seldom used to measure a size outright. It is a comparator, which shows how much one thing differs from another. The usual reference is a gauge block of accurately known size.
The indicator is lowered onto the block until the plunger is pressed in a little, so that the hand can move either way. The bezel is then turned to bring zero under the hand. When a part replaces the block, the hand shows the difference directly.
With a 25.00 mm block, a hand that stops 12 divisions clockwise of zero means the part is 0.12 mm bigger, or 25.12 mm. A hand that stops 6 divisions the other way points at 94 on the dial. Counting back from zero gives minus 0.06 mm, so the part is 24.94 mm.
The same idea checks whether a shaft runs true. The contact point rests on the shaft while it is turned once, and the hand swings between two extremes. Readings of plus 0.07 mm and minus 0.05 mm give a total indicator reading of 0.12 mm, which for a round shaft means its centre is 0.06 mm off the axis.
The plunger must point square at the surface. If it leans, it has to travel further than the surface actually moves, and the reading is too large. This is called cosine error.
Dirt or a knock to the gears shows up as a hand that fails to return to the same mark. Machinists lift the plunger slightly and let it down gently to test this.